| | * NOTE: Click on an image to enlarge it in a new window. | |
| | .jpg) | DFS Turbine Flow Meters
The DigiFlow DFS flowmeters provide low flow sensing capabilities in a wide range of end-user and OEM applications. Utilizing a rotor which, using an infrared beam, generates a digital signal, the DigiFlow concept offers high accuracy, low cost, and a flexible design to meet customer requirements. In either monitoring or flow controlled applications, the DFS series meters can measure flow rates and total quantities.
Design Features: Two ranges of 0.07 25 litres/minute (.02 6.6 GPM) Accuracy within +/-0.5% or better. Operational pressures up to 70 bar (1,000 PSIG) Quantity measurements as small as 0.1 ml. Housing of high quality polymers or machined metal. Wetted surfaces of high quality polymers. Compatible with most acids and bases. Low pressure drops Friction-free fluid bearings yielding long life. Infrared signal pick-up. Resolution of up to 65,000 pulses/litre (246,000/gallon). Turn down ratios of up to 64:1 Mount in any position without flow straighteners. | |
| | | |
| | .jpg) | DFS-2W / 3W Disposable Flowmeters Sterilizable Interchangeable/Disposable Flow Meter
The DigiFlow DFS-2W/3W flowmeters have been specifically designed for use in pharmaceutical, medical, food processing and other OEM/end-use applications requiring interchangeable or disposable components, or other high volume/low unit cost applications.
The basic flow meter consists of two major assemblies: A sterilizable, interchangeable/disposable rotor assembly which include all wetted surfaces. A permanent, fixed electronics/mounting assembly. Flowmeter design makes it an integral component of systems designed for accurate monitoring or flow control of liquids.
Design Features: Two ranges of 0.07 25 litres/minute (.02 6.6 GPM). Accuracy within 0.5%. Wetted surfaces of high quality polymers. Quantity measurements as small as 0.2 ml. Housing of high quality polymers. Friction free fluid bearings yielding long life. Low pressure drops. Compatible with most acids and bases. Infrared signal pick-up. Resolution of up to 60,000 pulses/litre (227,100/gallon). Turn down ratios of up to 64:1. Mount in any position without flow straighteners. | |
| | | |
| | .jpg) | DFS-20 Series Teflon Flowmeters
The DigiFlow DFS-20 Series Teflonฎ flowmeters provide flow sensing capabilities in a wide variety of end-use and OEM applications, including corrosive aqueous liquids. Utilizing a rotor which, using a reflected infrared beam, generates a digital signal. The DFS-20 series offers an accurate, economical, and flexible design to meet many customer requirements. In either monitoring or flow controlled applications, the DFS-20 series can measure flow rates and totalize. Design Features : Three ranges from 0.09 - 35 litres/minute (.025 9.2 GPM). Wetted surfaces of PFA Teflonฎ with ruby glass bearing. Outer housing of PFA or SS. Accuracy within 1% or better (0.15% repeatability). Low pressure drops. Infrared signal pickup. Mount in any position without flow straighteners. Interchangeable/Disposable rotor assembly option. CE mark approved. Fiber optic signal transmission option. | |
| | | |
| | .gif) | Liquid Flowmeters & Controllers
Liquid flowmeters and controllers of the L and LC series use two of the best-studied physical properties of liquids to measure flow: Viscosity and Pressure. Differential pressure measurement, across a laminar flow element, results in a flowmeter that is inherently linear. The flow meter measures differential pressure within that laminar region to achieve a turndown of 50:1 typical.
The L Series is a Volumetric Flowmeter. The unique method of flow detection allows the unit to measure extremely low flow rates at an affordable price. These flowmeters are available in ranges of 500 micro-liters per minute full scale to 10 liters per minute full scale. Units are suitable for low viscosity, non-aggressive liquids.
The LC Series Flow Controller utilized a proportional valve coupled to a flowmeter body creating a unique in-situ closed-loop flow controller system. Measurements are taken within the laminar region of the flow meter and the integral PID controller positions the valve according to the flow set points. These robust, closed-loop devices accept a selectable digital or analog control set point from either direct entry on units with local display or external devices. The controllers can also accept an RS-232, 0-10Vdc or 4-20mA control input signal depending on what is preferred by the customer. Independent of the set point voltages, the controllers can be configured for single or dual output of the same or different voltages and/or different parameters such as temerature and flow. This is possible because of the laminar flowmeter design which incorporates solid-state Differential, Absolute Pressure, and Temperature sensors to determine flow in an inherently linear system. The result is a fast responding linear flow meter with multiple outputs. All these parameters are simultaneously visible with our dynamic display that includes a push button operator interface. Liquid controllers are available from 500 micro-liters per minutes full scale to 500 milliliters per minute full scale. | |