Contact Details:
 PhoneSee Phone No 
   
E-mailE-mail Company
 Computer and GlobeVisit Website 
 
Dwyer Instruments, Inc.Michigan City, IN
 * NOTE: Click on an image to enlarge it in a new window. 
 Adjustable Range Pressure Transmitter
Series 634ES


• 0.5% Full Span Accuracy, Ranges to 5000 psi
 
   
 Digital Indicating Transmitter
Series DSGT


• ±0.25% Full Scale Accuracy, Optional Switch Outputs
 
   
 Pressure Indicating Transmitter
Series 619


• Turret Mount Case, 3-1/2" LCD, 0.5% F.S. Accuracy
 
   
 Spirahelic® Pressure Indicating Transmitter
Series 7116B


• Large, Turret Mount, Accurate to ±0.5% of Full Scale, 4-2 mA Output
 
   
 Spirahelic® Pressure Indicating Transmitter
Series 7116


• Dial Gage Indication, ±0.5% F.S. Accuracy, Panel Mount
 
   
 Weatherproof Pressure Transmitter
Series 679


• ±0.25% FS Accuracy, Compatible with Corrosive Materials, 4-20 mA Output
• Ranges from 25 to 10,000 psi (1.5 to 689 bar), Gas/Liquid, 17-4 PH SS, NEMA 4 (IP56)
 
   
 Pressure Transmitter
Series 638


• Stability, Stainless Steel, Intrinsically Safe, Accuracy ±0.50%, 4-20 mA Signal
• Ranges from 100 to 7500 psi (7 to 517 bar), Gas/Liquid/Vapor, 17-4 PH SS, NEMA 4X
 
   
 Intrinsically Safe Pressure Transmitter
Series IS626


• For use in Hazardous Locations
• Ranges from 30" Hg to 1500 psi, ±0.25% Accuracy, Gas/Liquid/Air
 
   
 Industrial Pressure Transmitter
Series 626 & 628


• Complete Offering of Ranges, Connections and Outputs
• Ranges from 15 to 1000 psi, ±0.25% Accuracy, Gas/Liquid/Air
• Conduit Housing (-CH)
 
   
 Industrial Pressure Transmitter
Series 626 & 628


• General Purpose Housing (-GH)
 
   
 Industrial Pressure Transmitter
Series 626 & 628


• LED Version (not NEMA 4X rated)
 
   
 Flush Diaphragm Transmitter
Series FDT


• Non-liquid Filled, ±0.5% F.S.O. Accuracy, SS Wetted Parts
• Ranges from 100 to 10,000 psi, Air/Gas/Liquid, 316 & 15-5 SS
 
   
 Differential Pressure Transducer
Series 683


• ±0.25% Accuracy, 17-4 PH Stainless Steel Wetted Parts, 4-20 mA or 5V Output
• Ranges from 15 to 1000 psi, 17-4 pH Stainless Steel
 
   
 Industrial Pressure Transmitter
Series 682


• ±0.13% FS Accuracy, External Adjustments, 4-20 mA Output
• Ranges from 25 to 10,000 psi (1.5 to 689 bar), Gas/Liquid, 17-4 PH SS, NEMA 4 (IP65)
 
   
 Pressure Transmitter
Series 673


• ±0.25% Full Span Accuracy, 4-20 mA Signal, Ranges to 1000 psi
• Ranges from 1 to 1000 psi (70 mbar to 68 bar), Gas/Liquid/Vapor, 17-4 PH SS
 
   
 Pressure Transmitter
Series 673


• Conduit Version
 
   
 Fixed Range Pressure Transmitter
Series 636


• 0.5% Full Span Accuracy, Ranges to 5000 psi
• Ranges from 15 to 300 psi (1 to 20 bar), ±0.30% Accuracy, Gas/Liquid/Vapor, 316L SS, NEMA 4
 
   
 Sanitary Pressure Transmitter
Series 681


• No Liquid Fill Diaphragm, Sanitary Clamp Fitting
• Ranges from 1 to 300 psi (68 mbar to 20 bar), ±0.2% Accuracy, Gas/Liquid, 316L SS
 
   
 Sanitary Pressure Transmitter
Series 637S


• Meets NACE Standards, Accuracy ±0.25%
• Ranges from 15 to 300 psi (1 to 20 bar), Gas/Liquid/Vapor, 316L SS
 
   
 Adjustable Range Pressure Transmitter
Series 637


• Stainless Steel, Intrinsically Safe, Explosion-proof, Accuracy ±0.25%, 4-20 mA Signal
• Ranges from 3 to 300 psi (0.2 to 20 bar), Gas/Liquid/Vapor, 316L SS, NEMA 4
 
   
 Magnesense® Differential Pressure Transmitter
Series MS


• Monitors Pressure and Air Velocity
• Selectable Ranges, ±1.0% Accuracy, Air/Gas
 
   
 Magnehelic® Differential Pressure Indicating Transmitter
Series 605


• Ranges from 0.5 to 50" w.c., ±0.5-2% Accuracy, Air/Gas
 
   
 Differential Pressure Indicating Transmitter
Series 620


• 1/16 DIN Housing, Digital Readout, 0.5% Full Scale Accuracy
• Ranges from 3" w.c. to 100 psid, ±0.5% Accuracy, Air/Gas
 
   
 Differential Pressure Indicating Transmitter
Series 621


• 1/8 DIN Housing, 0.5% Full Scale Accuracy
• Ranges from 3" w.c. to 100 psid, ±0.5% Accuracy, Air/Gas
 
   
 Minihelic® Differential Pressure Indicating Transmitter
Series 604D


• Ranges from 0.5 to 100" w.c., ±2% Accuracy, Air/Gas
 
   
 Differential Pressure Transmitter
Series DM-2000


• Same Size as Standard Magnehelic® Differential Pressure Gage
• Ranges from 0 to 0.5" w.c., ±1% Accuracy, Air/Gas Air/Gas
 
   
 Differential Pressure Transmitter
Series 607


• ±0.25% or ±0.5% F.S. Accuracy, Ranges from 0-0.1" w.c.
• Ranges from 0.1 to 5" w.c., Air/Gas
 
   
 Differential Pressure Transmitter
Series 603A



• Ranges from 0.2" w.c. to 30 psid
• Ranges from 0.2" w.c. to 10 psi, ±0.5% Accuracy, Air/Gas
 
   
 Wet/Wet Differential Pressure Transmitter
Series 645


• ±0.25% Accuracy, Quick Response, 2-wire Design
• Ranges from 1 to 100 psid, ±0.25% Accuracy, Gas/Liquid, NEMA 4X (IP56)
 
   
 Wet/Wet Differential Pressure Transmitter
Series 631B


• Ranges Down to 0.5" w.c. with 500 psi Static Pressure Rating
• Ranges from 0.5" w.c. to 25" w.c., ±2% Accuracy, Gas/Liquid, NEMA 4X (IP66)
 
   
 Differential Pressure Transmitter
Series 604A


•±2% Full Span Accuracy, Pressure Rated to 30 psig
 
   
 Low Differential Pressure Transmitter
Series 610


• Ideal for Clean Rooms
• Ranges from 0.1 to 10" w.c., ±0.25% Accuracy, Air/Gas, NEMA 2
 
   
 Differential Pressure Transducer
Series WWDP


• Selectable Ranges of Uni-Directional or Bi-Directional, ±1% Accuracy, Gas/Liquid, Selectable Outputs
 
   
 One-Touch™ Differential Pressure Transmitter
Series 616OT


• One Button Calibration Reduces Installation and Calibration Time
• Ranges from 10" w.c. to 5 kPa, ±1% Accuracy, Air/Gas
 
   
 Differential Pressure Transmitter
Series 674


• ±1% FS Accuracy, Up to Six Field Selectable Ranges, 10 psid Overpressure
• Ranges from 0.1 to 30" w.c., ±1% Accuracy, Air/Gas, NEMA 4 (IP56)
 
   
 Rangeable Differential Pressure Transmitter
Series 666


• Field Selectable Pressure Ranges, 10 psig Overpressure, ±1% Accuracy
• Ranges from 0.1 to 30" w.c., ±1% Accuracy, Air/Gas, NEMA 4 (IP65)
 
   
 Wet/Wet Differential Pressure Transmitter
Series 629


• 0.5% Accuracy, NEMA 4X Enclosure
• Ranges to 100 psid, Gas/Liquid, NEMA 4X (IP66)
• Series 629 shown with optional cable gland
 
   
 Wet/Wet Differential Pressure Transmitter
Series 629


• Series 629 shown with optional LED
 
   
 Wet/Wet Differential Pressure Transmitter
Series 647


• Ranges from 0 to 1" w.c., ±1.0% Accuracy, NEMA 4 Enclosure, 2-wire
• Ranges from 1" w.c. to 30 psid, Gas/Liquid, NEMA 4 (IP56)
 
   
 Differential Pressure Transducer
Series 646


Low Cost, Ranges from ±0.5" w.c., Voltage Output
Ranges from 0.5 to 10" w.c., ±1% Accuracy, Air/Gas, Voltage Output
 
   
 Differential Pressure Transmitter
Series 608


• Ranges Down to 0.1" w.c., Intrinsically Safe, NEMA 4X
• Ranges from 0.1 to 25" w.c., ±0.25% Accuracy, Air/Gas, NEMA 4X
 
   
 Differential Pressure Transmitter
Series 677


• Ranges Down to 0.1" w.c., Low Cost, ±0.4% Accuracy, 4 to 20 mA Output
• Ranges from 0.1 to 100" w.c., Air/Gas, Brass
 
   
 Differential Pressure Transmitter
Series 616 & 616C


• Ranges from 0-1" w.c. to 0 to 100 psid, Accuracy ±0.25% or ±1% F.S.
• Ranges from 1" w.c. to 100 psid, ±0.25% Accuracy, Air/Gas
 
   
 Differential Pressure Transmitter
Series 616W


• NEMA 4X Enclosure, ±0.25% F.S. Accuracy, Ranges from 0-1" w.c. to 0-100 psid
• Ranges from 1" w.c. to 100 psid (500 Pa to 25 kPa), ±0.5% Accuracy, Air/Gas, NEMA 4X
 
   
 Differential Pressure Transmitter
Series 648


• Ranges Down to 0.1" w.c., ±1% Accuracy, High Overpressure Protection
• Ranges from 0.1 to 10" w.c., Air/Gas, NEMA 1
 
   
 Differential Pressure Transmitter
Series 668


• Ranges from 0 to 0.25" w.c., Overpressure Protection to 10 psig, ±1% Accuracy
• Ranges from 0.25 to 100" w.c., ±1% Accuracy, Air/Gas
 
   
 Fixed Range Differential Pressure Transmitter
Series 636D


• Explosion-proof, 0.5% Accuracy
• Ranges from 6 to 500 psid, ±0.5% Accuracy, Gas/Liquid, Fixed Range
 
   
 Duct Pressure Transmitter
Series 676


•±1% FS Accuracy, NEMA 4 (IP56) Enclosure, Three Field Selectable Ranges
• Ranges from 1.25 to 15" w.c., ±1% Accuracy, Air/Gas, NEMA 4 (IP56)
 
   
 Wet/Wet Differential Pressure Transmitter
Series 655


• Low Range, 0-5" w.c., High Maximum Working Pressure
• Range to 5" w.c. (1.24 kPa), ±0.5% Accuracy, Gas/Liquid, 316 SS, 316L SS
 
   
 Differential Pressure Transmitter
Series 616D


• Mounts on 35 mm DIN Rail
• Ranges from 3" w.c. to 100 psid, ±0.25% Accuracy, Air/Gas, DIN Rail Mount
 
 

New Search