![]() | Exergen Corp. | Watertown, MA | ![]() |
| |||||||||
* Click on an image to enlarge it in a new window * | |||||||||
![]() | IRt/c.01 Key features: • Sensing Range: -50 to 550 °F (-45 to 290 °C) • Ambient Temperature Range: 0 to 160 °F (-18 to 70 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 1:1 (60°) approximately • Minimum Spot Size: 0.3" (8 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 3 Kohms approximately • Cable: Thermocouple extension grade, PVC jacket, unshielded • Dimensions: 1.28" x .71" Diameter (32.5 x 20 mm) • Weight: 1.4 oz (40 g) with cable • Housing: High strength ABS, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe. Two locknuts supplied. | ||||||||
![]() | IRt/c.03 Key features: • Sensing Range: -50 to 550 °F (-45 to 290 °C) • Ambient Temperature Range: 0 to 160 °F (-18 to 70 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 3:1 (17°) approximately • Minimum Spot Size: 0.25" (6 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 4 to 8 Kohms approximately • Cable: Thermocouple extension grade, PVC jacket, unshielded • Dimensions: 1.49" x .71" Diameter (37.8 x 20 mm) • Weight: 1.4 oz (40 g) with cable • Housing: High strength ABS, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe. Two locknuts supplied. | ||||||||
![]() | IRt/c Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Ambient Temperature Range: 0 to 212 °F (-18 to 100 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 1:1 (60°) approximately • Minimum Spot Size: 0.3" (8 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 3 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 1.75" x .50" Diameter (44 x 12.7 mm) • Weight: 1.4 oz (40 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. | ||||||||
![]() | IRT/c.3X Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 3:1 (17°) approximately • Minimum Spot Size: 0.25" (6 mm) • Spectral Response: 6.5 to 14 µ (2 to 20 µ with IRt/c.3XG germanium lens) • Output Impedance: 4 to 8 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 1.76" x .50" Diameter (44.7 x 12.7 mm) • Weight: 1.4 oz (40 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. • Air Purge: Built-in; designed for severe paint or ink environment; 3; (0.9 m) of tubing provided. | ||||||||
![]() | IRt/c.SV Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Ambient Temperature Range: 0 to 212 °F (-18 to 100 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 1:1 (60°) approximately • Minimum Spot Size: 0.3" (8 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 3 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 2.27" x .50" Diameter (57.8 x 12.7 mm) • Weight: 1.4 oz (40 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. | ||||||||
![]() | IRt/c.1X Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Ambient Temperature Range: 0 to 212 °F (-18 to 100 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 1:1 (60°) approximately • Minimum Spot Size: 0.3" (8 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 3 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 1.43" x .50" Diameter (36 x 12.7 mm) • Weight: 1.4 oz (40 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. | ||||||||
![]() | IRt/c.3SV Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 3:1 (17°) approximately • Minimum Spot Size: 0.2" (5 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 4 to 8 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 2.27" x .50" Diameter (44.7 x 12.7 mm) • Weight: 1.6 oz (44 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. • Air Purge: Built-in; designed for severe paint or ink environment; 3; (0.9 m) of tubing provided. | ||||||||
![]() | IRt/c.5 Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 5:1 (11°) approximately • Minimum Spot Size: 0.8" (20 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 4 to 8 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 3.4" x 1.375" Diameter (86 x 35 mm) • Weight: 6.5 oz (184 g) with cable • Housing Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. • Air Purge Built-in; cooling capacity to 400 °F (200 °C) ambient; 3; (0.9 m) polyurethane tubing provided | ||||||||
![]() | IRt/c.10 Key features: • Sensing Range: -50 to 1200 °F (-45 to 650 °C) • Optimum Range Selections: Eight models per t/c type (see Temperature Selection Guide) • Field-of-View: 10:1 (6°) approximately • Minimum Spot Size: 0.8" (20 mm) • Spectral Response: 6.5 to 14 µ • Output Impedance: 4 to 8 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (K ONLY), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 3.76" x 1.375" Diameter (96 x 35 mm) • Weight: 6.5 oz (184 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. • Air Purge: Built-in; cooling capacity to 400 °F (200 °C) ambient; 3; (0.9 m) polyurethane tubing provided | ||||||||
![]() | IRt/c.2GJ37C Special Performance Medical Model Key features: • Sensing Range: Human Body Temperature • Optimum Range Selections: +/- 0.2° C from 35.5 to 39.4° C , +/- 0.3° C from 25 to 40° C • Field-of-View: 1:1 (60°) approximately • Minimum Spot Size: 0.16" (4 mm) • Spectral Response: 2 to 20µ • Output Impedance: 10 Kohms approximately • Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. • Dimensions: 1.75" x .500" Diameter (44 x 12.7 mm) • Weight: 1.4 oz (40 g) with cable • Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. • Air Purge: none | ||||||||
![]() | IRt/c.2 Key features: • Sensing Range: -50 to 2000° F (-45 to 1100° C • Linear Range: 8 Models per thermocouple type • Field-of-View: 35° approximately • Minimum Spot Size: 0.16" (4 mm) • Output Impedance: 4 to 8 Kohms (varies by model) • Dimensions: 2.45" x 0.5" Diameter (62 x 13 mm) • Weight: 1.6 oz (44 g) with cable • Air Purge: Built-in | ||||||||
![]() | IRt/c.07 • Ambient Temperature Range: -4 °F - 158 °F (-20 °C - 70 °C) (internal case temperature) • Storage Temperature Range: -4 °F - 158 °F (-20 °C - 70 °C) • Field of View of Sensing Element: 7:1 (distance: spot) approximately 8o inclusive • Minimum Spot size: 0.75" (19 mm) • Dominant Spectral Response: 6.5 to 14 μm • Output Sensor: K type thermocouple • Impedance: 3.5 – 14 Kohms, varies depending on temperature range • Emissivity (ε): .90 • Measurement Type: Thermopile • Resolution: Approximately 0.0003 °C, Johnson Noise • Update Time: Instantaneous • Time Constant: 100 milliseconds typically • Response Time (95% of step change): 300 milliseconds • Accuracy (Interchangeability): 1% at factory calibration conditions • Dimensions: 3.25" x 1.18" Dia. (82.5 x 29.97 mm Dia.), M30 x 1.5 thread • Housing: ABS Black Plastic • Cable Assembly: 3 feet of unshielded, duplex insulated, type K, 24 AWG, PFA jacket rated to 392 °F (200 °C) (Shielded cable available upon request) • Humidity: Non-Condensing • Power Requirements: None • Sealed: Hermetically, exceeds NEMA 4X, IP67 • Weight: Approximately 2.3 oz (65 grams) | ||||||||
![]() | microIRt/c The World's Smallest and Lowest Cost IRt/cTM Key features: • Small Size • Lowest Cost • Variety of mounting options • Self powered • Air purge (optional) | ||||||||
![]() | microIRt/c.SV Key features: • Side view mount • Self powered • Small size • Mounting rings | ||||||||
![]() | micro IRt/c.4 Key features: • Self powered • Small size • Low cost • Mounting rings • Air purge available • 4:1 field of view • Measure higher temperature ranges • Repeatable signal • High interchangeability • Highly Reliable | ||||||||
![]() | micro IRt/c.4SV Key features: • Side view mount • Self powered • Small size • Mounting rings • Built in Air purge • 4:1 field of view • High temperature range with signal output tables available | ||||||||
![]() | IRt/c.01Z Key features: • Sensing Range: -50 to 550 °F (-45 to 290 °C) • Ambient Temperature Range: 0 to 160 °F (-18 to 70 °C) • Optimum Range Selections: Eight models per K t/c type (see Temperature Selection Guide) • Field-of-View: 1:1 (60°) approximately • Minimum Spot Size: 0.3" (8 mm) • Spectral Response: 6.5 to 14 μ • Output Impedance: 15 to 40 Kohms approx • Cable: K type, thermocouple extension grade, PVC jacket, unshielded • Dimensions: 1.28" x 0.71 Dia. (32.5 x 20.0 mm Dia.) • Weight: 1.4 oz (40 g) with cable • Housing: High Strength ABS, hermetically sealed, exceeds NEMA 4X and IP67 intrinsically safe. Two locknuts supplied. |
![]() | ![]() |